From version < 12.1 >
edited by Randell Greenlee
on 2021/08/25 09:10
To version < 16.1 >
edited by Eric deRuijter
on 2022/01/12 14:22
< >
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.RandellGreenlee
1 +XWiki.EricDeRuijter
Content
... ... @@ -24,7 +24,7 @@
24 24  
25 25  == [[Development notes>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Development notes.WebHome]] ==
26 26  
27 -Status: **In progress** / second read** **/ finalised (date)
27 +Status: In progress / **second read **/ finalised (date)
28 28  
29 29  (The notes below will be removed at the end of the project)
30 30  
... ... @@ -31,7 +31,7 @@
31 31  (% class="box errormessage" %)
32 32  (((
33 33  (% class="wikigeneratedid" id="HStatus-weneedtocheckthesectorallayer" %)
34 -**Methods / Training / References**
34 +**References**
35 35  \\
36 36  )))
37 37  
... ... @@ -41,8 +41,12 @@
41 41  
42 42  (% class="wikigeneratedid" %)
43 43  (((
44 -Work safely with
44 +==== Scope Note: ====
45 45  
46 +In some Member States, occupational health and safety regulations apply. These dictate special competences and relate to local regulations and standards.
47 +
48 +The power distribution systems described here are temporary systems, either connected to a permanent power supply or a generator.
49 +
46 46  === [[Structure>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Structure.WebHome]] ===
47 47  
48 48  (% style="width:618.25px" %)
... ... @@ -60,37 +60,27 @@
60 60  
61 61  ==== [[Skills>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Skills.WebHome]] ====
62 62  
63 -Provide power distribution for light, stage, sound, video and rigging purposes
67 +* Provide power distribution for light, stage, sound, video and rigging purposes
68 +* Calculate mono-phase electric loads
69 +* Put cables, fuse boards and splitters in place, based on instructions
70 +* Connect, label, protect, and secure cables
71 +* Perform visual inspections for electrical risks
72 +* Troubleshoot basic problems: checking cables, connections, …
73 +* Act according to the agreed procedure in case of an electrical accident
64 64  
65 -Calculate mono-phase electric loads
66 -
67 -Put cables, fuse boards and splitters in place, based on instructions
68 -
69 -Connect, label, protect, and secure cables
70 -
71 -Perform visual inspections for electrical risks
72 -
73 -Troubleshoot basic problems: checking cables, connections, …
74 -
75 -Act according to the agreed procedure in case of an electrical accident
76 -
77 77  ==== [[Knowledge>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Knowledge.WebHome]] ====
78 78  
79 -Basic electrical concepts and calculations
77 +* Basic electrical concepts and calculations
78 +* Electrical Risks
79 +* Protection against electrical risks
80 +* Cables and connections
81 +* Body protection
82 +* Eye and face protection
80 80  
81 -Electrical Risks
82 -
83 -Protection against electrical risks
84 -
85 -Cables and connections
86 -
87 -Body protection
88 -
89 -Eye and face protection
90 -
91 91  ==== [[Autonomy / attitude>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Autonomy - attitude.WebHome]] ====
92 92  
93 -Awareness of invisible risks Awareness of others’ behaviour
86 +* Awareness of invisible risks
87 +* Awareness of others’ behaviour
94 94  
95 95  ----
96 96  
... ... @@ -112,12 +112,12 @@
112 112  
113 113  ==== [[Acceptable assessment methods>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Acceptable assessment methods.WebHome]] ====
114 114  
115 -* [[Observation in simulated environment>>url:https://wiki.sv-wtu.at/xwiki/bin/view/Main/Sectoral%20Layer/Sectoral%20Layer%20Glossary/Observation%20in%20simulated%20environment/]]
116 -* [[Observation on site>>url:https://wiki.sv-wtu.at/xwiki/bin/view/Main/Sectoral%20Layer/Sectoral%20Layer%20Glossary/Observation%20on%20site/]]
109 +* [[Observation in a Simulated Environment>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Observation in simulated environment.WebHome]]
110 +* [[Observation on Site>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Observation on Site.WebHome]]
117 117  
118 118  Supportive:
119 119  
120 -* [[Structured portfolio>>url:https://wiki.sv-wtu.at/xwiki/bin/view/Main/Sectoral%20Layer/Sectoral%20Layer%20Glossary/Structured%20portfolio/]]
114 +* [[Structured Portfolio>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Structured Portfolio.WebHome]]
121 121  
122 122  ----
123 123  
... ... @@ -130,38 +130,21 @@
130 130  
131 131  === [[References>>doc:01 Sectoral Layer.Sectoral Layer Glossary.References.WebHome]] ===
132 132  
133 -==== EU ====
134 -
127 +* (((
128 +Netherlands: Qualification File Stage and Event Technology, crebonumber 79040, learning area B1-K1: Bereidt de podiumproductie technisch voor. SBB, Sectorchambre ICT and Creative Industry, version 2022 (to be released August 2022), Zoetermeer 2021.
129 +)))
130 +* (((
135 135  ETTE
132 +)))
133 +* (((
134 +BE: Codex over het welzijn op het werk, Boek III.- Arbeidsplaatsen, Titel 2.– Elektrische installaties, [[http:~~/~~/www.werk.belgie.be/WorkArea/DownloadAsset.aspx?id=46037>>http://www.werk.belgie.be/WorkArea/DownloadAsset.aspx?id=46037]] AREI, Algemeen Reglement op de Elektrische installaties (Belgium) (General Legislation for Electrical Installations of Belgium) In Belgium an employee needs a BA4 certificate delivered by employer for each situation. All tasks of a BA4 holder should be supervised by someone holding a BA5 certificate delivered by the employer.
135 +)))
136 +* (((
137 +DE: RICHTLINIE 2006/95/EG DES EUROPÄISCHEN PARLAMENTS UND DES RATES vom 12. Dezember 2006 zur Angleichung der Rechtsvorschriften der Mitgliedstaaten betreffend elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen: http:~/~/www.dgwz.de/wp-content/uploads/Niederspannungsrichtlinie-2006-95-EG-NSRLVD. pdf / SQP4 – Mobile elektrische Anlagen in der Veranstaltungstechnik
138 +)))
139 +* (((
140 +NL: NEN 1010; norm voor elektrotechnische laagspanningsinstallaties in woningen, gebouwen en infrastructuur / NEN 3140:2011 nl, Bedrijfsvoering van elektrische installaties - Laagspanning / NEN 8020-20:2011 nl, Evenementen - Elektrische installaties / NPR 5310:2017 nl, Nederlandse praktijkrichtlijn bij NEN 1010
141 +)))
136 136  
137 137  
138 -==== BE ====
139 -
140 -Codex over het welzijn op het werk, Boek III.- Arbeidsplaatsen, Titel 2.– Elektrische installaties, [[http:~~/~~/www.werk.belgie.be/WorkArea/DownloadAsset.aspx?id=46037>>http://www.werk.belgie.be/WorkArea/DownloadAsset.aspx?id=46037]]
141 -
142 -AREI, Algemeer Reglement op de Elektrische installaties (Belgium) (General Legislation for Electrical Installations of Belgium)
143 -
144 -In Belgium an employee needs a BA4 certificate delivered by employer for each situation. All tasks of a BA4 holder should be supervised by someone holding a BA5 certificate delivered by the employer.
145 -
146 -
147 -==== DE ====
148 -
149 -RICHTLINIE 2006/95/EG DES EUROPÄISCHEN PARLAMENTS UND DES RATES vom 12. Dezember 2006 zur Angleichung der Rechtsvorschriften der Mitgliedstaaten betreffend elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen: http:~/~/www.dgwz.de/wp-content/uploads/Niederspannungsrichtlinie-2006-95-EG-NSRLVD. pdf
150 -
151 -SQP4 – Mobile elektrische Anlagen in der Veranstaltungstechnik
152 -
153 -==== NL ====
154 -
155 -NEN 1010; norm voor elektrotechnische laagspanningsinstallaties in woningen, gebouwen en infrastructuur.
156 -
157 -NEN 3140:2011 nl, Bedrijfsvoering van elektrische installaties - Laagspanning
158 -
159 -NEN 8020-20:2011 nl, Evenementen - Elektrische installaties
160 -
161 -NPR 5310:2017 nl, Nederlandse praktijkrichtlijn bij NEN 1010
162 -
163 -
164 -==== Links to further reading ====
165 -
166 -
167 167