Show last authors
1 {{box cssClass="floatinginfobox" title="**Contents**"}}
2 {{toc/}}
3 {{/box}}
4
5 = **Work safely with mobile electrical systems under supervision** (60 45 00 03 07) =
6
7 == [[ESCO description>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Sectoral layer ESCO description.WebHome]] ==
8
9 (% style="width:691.25px" %)
10 |(% style="width:179px" %)**[[Title>>path:/xwiki/bin/view/Main/Sectoral%20Layer/Sectoral%20Layer%20Glossary/Title/]]**|(% style="width:509px" %)Work safely with mobile electrical systems under supervision
11 |(% style="width:179px" %)**[[Description>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Sectoral layer ESCO description.WebHome]]**:|Take the necessary precautions while providing temporary power distribution for performance and art facility purposes under supervision.
12 |(% style="width:179px" %)**[[Scope note>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Scope note.WebHome]]**:|(% style="width:509px" %)This competence is limited to mobile, temporary installations with connectors. In some countries, workers are only alowed to perform this kind of actions under supervision of a qualified person.
13 |(% style="width:179px" %)[[**Concept URI**>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Concept URI.WebHome]]:|(% style="width:509px" %)[[http:~~/~~/data.europa.eu/esco/skill/b69cb255-e939-4928-b3fd-9557087dce52>>http://data.europa.eu/esco/skill/b69cb255-e939-4928-b3fd-9557087dce52]]
14 |(% style="width:179px" %)[[**ESCO version**:>>doc:01 Sectoral Layer.Sectoral Layer Glossary.ESCO version.WebHome]]|(% style="width:509px" %)1.08
15
16 === [[In other languages>>doc:01 Sectoral Layer.Sectoral Layer Glossary.In other languages.WebHome]] ===
17
18 (% style="width:1193.25px" %)
19 |(% style="width:180px" %)Deutsch:|(% style="width:1012px" %)**unter Aufsicht sicher mit mobilen elektrischen Systemen arbeiten**
20 |(% style="width:180px" %)Nederlands:|(% style="width:1012px" %)**veilig met mobiele elektrische systemen onder toezicht werken**
21 |(% style="width:180px" %)Italiano:|(% style="width:1012px" %)**lavorare sotto supervisione e in sicurezza con i sistemi elettrici mobili**
22
23 ----
24
25 == [[Development notes>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Development notes.WebHome]] ==
26
27 Status: **In progress** / second read** **/ finalised (date)
28
29 (The notes below will be removed at the end of the project)
30
31 (% class="box errormessage" %)
32 (((
33 (% class="wikigeneratedid" id="HStatus-weneedtocheckthesectorallayer" %)
34 **Methods / Training / References**
35 \\
36 )))
37
38 ----
39
40 == [[Sectoral layer>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Sectoral layer.WebHome]] ==
41
42 (% class="wikigeneratedid" %)
43 (((
44 Work safely with
45
46 === [[Structure>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Structure.WebHome]] ===
47
48 (% style="width:618.25px" %)
49 |(% style="width:268px" %)[[Field and subfield>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Field and subfield.WebHome]]:|(% style="width:347px" %)60 45
50 |(% style="width:268px" %)[[Place in the process>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Place in the process.WebHome]]:|(% style="width:347px" %)00
51 |(% style="width:268px" %)[[Level>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Level.WebHome]]:|(% style="width:347px" %)03
52 |(% style="width:268px" %)[[Unique identifier:>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Unique identifier.WebHome]]|(% style="width:347px" %)07
53
54
55 )))
56
57 ----
58
59 === [[Sectoral detail>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Sectoral detail.WebHome]] ===
60
61 ==== [[Skills>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Skills.WebHome]] ====
62
63 Provide power distribution for light, stage, sound, video and rigging purposes
64
65 Calculate mono-phase electric loads
66
67 Put cables, fuse boards and splitters in place, based on instructions
68
69 Connect, label, protect, and secure cables
70
71 Perform visual inspections for electrical risks
72
73 Troubleshoot basic problems: checking cables, connections, …
74
75 Act according to the agreed procedure in case of an electrical accident
76
77 ==== [[Knowledge>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Knowledge.WebHome]] ====
78
79 Basic electrical concepts and calculations
80
81 Electrical Risks
82
83 Protection against electrical risks
84
85 Cables and connections
86
87 Body protection
88
89 Eye and face protection
90
91 ==== [[Autonomy / attitude>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Autonomy - attitude.WebHome]] ====
92
93 Awareness of invisible risks Awareness of others’ behaviour
94
95 ----
96
97 === [[Assessment>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Assessment.WebHome]] ===
98
99 ==== [[Self assessment>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Self assessment.WebHome]] ====
100
101 1. I don't know how to take the necessary precautions while providing temporary power distribution independently. measure and power up an installation.
102 1. I am uncertain how to take the necessary precautions while providing temporary power distribution independently. measure and power up an installation.
103 1. I know how to take the necessary precautions while providing temporary power distribution independently. measure and power up an installation.
104 1. I am more than able to take the necessary precautions while providing temporary power distribution independently. measure and power up an installation.
105
106 ==== [[Mentor assessment>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Mentor assessment.WebHome]] ====
107
108 1. ... doesn't know how to take the necessary precautions while providing temporary power distribution independently. measure and power up an installation.
109 1. ... is uncertain how to take the necessary precautions while providing temporary power distribution independently. measure and power up an installation.
110 1. ... knows how to take the necessary precautions while providing temporary power distribution independently. measure and power up an installation.
111 1. ... is more than able take the necessary precautions while providing temporary power distribution independently. measure and power up an installation.
112
113 ==== [[Acceptable assessment methods>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Acceptable assessment methods.WebHome]] ====
114
115 * [[Observation in simulated environment>>url:https://wiki.sv-wtu.at/xwiki/bin/view/Main/Sectoral%20Layer/Sectoral%20Layer%20Glossary/Observation%20in%20simulated%20environment/]]
116 * [[Observation on site>>url:https://wiki.sv-wtu.at/xwiki/bin/view/Main/Sectoral%20Layer/Sectoral%20Layer%20Glossary/Observation%20on%20site/]]
117
118 Supportive:
119
120 * [[Structured portfolio>>url:https://wiki.sv-wtu.at/xwiki/bin/view/Main/Sectoral%20Layer/Sectoral%20Layer%20Glossary/Structured%20portfolio/]]
121
122 ----
123
124 === [[Training>>doc:01 Sectoral Layer.Sectoral Layer Glossary.Training.WebHome]] ===
125
126 * Initial training can best be done in a protected environment, like a workshop, separate from the complexity of a stage.
127 * Permanent repeated briefings on specific issues can keep the attention high.
128
129 ----
130
131 === [[References>>doc:01 Sectoral Layer.Sectoral Layer Glossary.References.WebHome]] ===
132
133 ==== EU ====
134
135 ETTE
136
137
138 ==== BE ====
139
140 Codex over het welzijn op het werk, Boek III.- Arbeidsplaatsen, Titel 2.– Elektrische installaties, [[http:~~/~~/www.werk.belgie.be/WorkArea/DownloadAsset.aspx?id=46037>>http://www.werk.belgie.be/WorkArea/DownloadAsset.aspx?id=46037]]
141
142 AREI, Algemeer Reglement op de Elektrische installaties (Belgium) (General Legislation for Electrical Installations of Belgium)
143
144 In Belgium an employee needs a BA4 certificate delivered by employer for each situation. All tasks of a BA4 holder should be supervised by someone holding a BA5 certificate delivered by the employer.
145
146
147 ==== DE ====
148
149 RICHTLINIE 2006/95/EG DES EUROPÄISCHEN PARLAMENTS UND DES RATES vom 12. Dezember 2006 zur Angleichung der Rechtsvorschriften der Mitgliedstaaten betreffend elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen: http:~/~/www.dgwz.de/wp-content/uploads/Niederspannungsrichtlinie-2006-95-EG-NSRLVD. pdf
150
151 SQP4 – Mobile elektrische Anlagen in der Veranstaltungstechnik
152
153 ==== NL ====
154
155 NEN 1010; norm voor elektrotechnische laagspanningsinstallaties in woningen, gebouwen en infrastructuur.
156
157 NEN 3140:2011 nl, Bedrijfsvoering van elektrische installaties - Laagspanning
158
159 NEN 8020-20:2011 nl, Evenementen - Elektrische installaties
160
161 NPR 5310:2017 nl, Nederlandse praktijkrichtlijn bij NEN 1010
162
163
164 ==== Links to further reading ====
165
166
167